PONDMASTER - Diaphragm Replacement Kit for AP-20 Aquarium Air Pump - 1 Kit

Product Description
£11.49
Danner Supreme Diaphragm Replacement Kit is designed to fit aquarium air pump 59943 AP-20. Diaphragm edge wall must be inserted in to the diaphragm retainer with the proper side facing into the groove in the retainer. The deeper side of the diaphragm will always face into the retainer groove. This kit includes diaphragms, flapper valves, plastic slip washers and bottom pressure chamber gasket; some models also include rubber plug sets to seal the flapper valve housing.

Package Description: 1 Kit

Serving Size: ..

Number of Servings: ..

  • Complete Rebuild Kit to repair one air pump
  • Kit Contents

    (2) x LP20 Diaphragm
    (4) x LP20 Washer
    (4) x LP20 Valve
    (2) x LP21 Diaphragm
    (4) x LP21 Washer
    (4) x Air Inlet and Outlet Rubber Stopper Set LP20
    (4) x Air Inlet and Outlet Rubber Stopper Set LP21
    (1) x Bottom Silicone Gasket
    (1) x Instructions

INSTALLATION INSTRUCTIONS: This kit includes diaphragms, flapper valves, plastic slip washers and bottom pressure chamber gasket; some models also include rubber plug sets to seal the Flapper Valve housings.

• Work in clear work space to avoid loosing parts.
• Organize screws as they are removed to avoid mix-ups.
• There are two diaphragm assemblies on opposite sides of the motor; work on one side at a time.

1. Disconnect the pump from the AC receptacle and from any hoses.
2. Remove the cover lid by removing screws on bottom.
3. Unscrew the diaphragm / flapper combination assembly from either end of the pump and separate the two parts. Parts may vary from those pictured here. Note that for the AP-20 kit there are two different sets of diaphragm parts to accommodate two different models. Use the set that matches your model and discard the other. Pry out the rubber diaphragm and clean the diaphragm housing with soap and water before re-assembly.
4. Open the Flapper Valve Housing, remove the flapper valves and replace with the new ones. Be sure to maintain the same front and back side orientation of the flapper valves.
5. Remove the round diaphragm completely and replace with the new Diaphragm and slip washers supplied.
6. Replace the diaphragm / flapper assembly and refasten.
7. Replace the cover lid.

Caution: FOR YOUR PROTECTION, ALWAYS UNPLUG THE UNIT FROM ITS POWER SOURCE BEFORE INSTALLING OR SERVICING. SHOULD THE UNIT APPEAR TO BE NOT WORKING, DO NOT ATTEMPT TO REACH, REMOVE, OR DISASSEMBLE BEFORE DISCONNECTING FROM THE POWER SOURCE.

1. This pump is solely intended to pump air. Do not use for oil, solvents, or any petroleum products (gasoline, diesel, etc.).
2. ALWAYS use a properly grounded AC outlet. Do not immerse the pump's plug in water or attempt to plug into electric receptacle if plug is wet.
3. Provide a "drip loop" for the line cord. This is a loop in the cord below the level of the receptacle or plug that prevents water from traveling along the cord in the direction of the receptacle.
4. Be sure that a ground fault circuit interrupter (GFCI) is installed in the branch circuit supplying the aquarium, fountain, or pond equipment.
5. NEVER remove the ground pin from the plug.

HEALTHCARE DISCLAIMER

The products sold on this site are not approved to diagnose, treat, cure or prevent disease. Information on this site including any product label or packaging should not be considered as a substitute for advice from a healthcare professional.

 

This Site is not intended to provide diagnosis, treatment or medical advice. Products, services, information and other content provided on this Site, including information that may be provided on this Site directly or by linking to third-party websites are provided for informational purposes only. Please consult with a physician or other healthcare professional regarding any medical or health related diagnosis or treatment options.

 

Always check the product label or packaging prior to using any product. If there are discrepancies, customers should follow the information provided on the product label or packaging. You should contact the manufacturer directly for clarification as to product labeling and packaging details and recommended use. Please also consult your physician for a complete list of indications, warnings, precautions, adverse events, clinical results, and other important medical information.

 

All Vitamin Grocer orders are shipped from the East Coast of the United States. Vitamin Grocer offers two shipping options with different costs depending upon whether or not your order value is greater than £30. The standard processing time for all orders is 2 business days.

Vitamin Grocer's standard shipping option is DHL eCommerce's Packet International service. DHL transports the package from the Vitamin Grocer warehouse to your local mail carrier who delivers the package to your front door. Orders over £30 ship for FREE using this service. See table below for more details.

In addition, Vitamin Grocer now offers a shipping option with door-to-door tracking for an additional charge. This service is DHL eCommerce's ePacket service. Unlike our standard service, which generally only provides tracking up to the port of entry of the destination country. ePacket provides door-to-door tracking with delivery confirmation. See below for rates and additional details.

 

NOTE : ORDER VALUES AFTER ALL DISCOUNTS HAVE BEEN APPLIED ARE USED IN CALCULATIONS FOR FREE SHIPPING

 

 

 SHIPPING OPTIONS

ORDERS LESS THAN £30

ORDERS GREATER THAN £30

FREQUENTLY ASKED QUESTIONS 

 

[powr-faq id=4141c34f_1496769733]

 

 

Vitamin Grocer UK is a property of Lycka, LLC

2221 Industrial Highway

York, PA 17402

USA